Tradestation User Group Germany (http://www.tradernet.org/wbb/index.php)
|- Posts aus dem alten Userforum (http://www.tradernet.org/wbb/board.php?boardid=15)
|-- Install Problem WinNT4.0 (http://www.tradernet.org/wbb/threadid.php?boardid=15&threadid=206)


Geschrieben von _Steffen am 08.11.2001, 07:10:

  Install Problem WinNT4.0

Möchte die TS2000i auf Win NT4.0 installieren und bekomme jedesmal am Ende der Installation nach "verify all" die Fehlermeldung "Komponente wurde in der Registrierung nicht gefunden OmegaFundamental32" Fehlermeldung mit OK bestätigen und die Install bricht ab.
WinNT4.0 wurde völlig neu mit SP5 installiert. Keine Änderung.

Wer kann helfen?
Danke. Steffen


Geschrieben von _Michael Kühn am 09.11.2001, 15:10:

  RE: Install Problem WinNT4.0

Hi,

der technical support des Herstellers sagt hierzu folgendes:

>This document discusses how to manually register an application that is not properly entered into the system registry. This procedure will be necessary when an application that is attempting to be started returns an error message stating that the application is not properly entered in the system registry.

How To:
Follow these steps to manually register an application. This procedure uses the TradeStation executable. For other applications, please refer to the table in the Known Issues section below.

1. Close all applications.

2. Click on Start | Run.

3. Type the line "Crogra~1Omegar~1Program s32.exe /regserver" without the quotes were C is the drive letter where the program was installed. This example uses the default directory path of Program FilesOmega Research, if you installed to a different directory path, use the appropriate path. The ~1 usage in the above example replaces the long filename present in Windows. Long filenames (directories or files with names longer than 8 characters) should not be used when manually registering an application. The first 6 letters of the directory followed by the ~1 for the first directory created. A second directory named Program Directory that had been created after Program Files would use the name Progra~2. In most cases, ~1 will always be used.

4. Click the OK button.

Known Issues:
The same procedure will need to be completed for each improperly registered application. Refer to the table below to find out which *.exe file will need to be used for each application or component.

ProSuite Desktop, TradeStation Desktop, or OptionStation Desktop
ORTrade.exe

TradeStation
ts32.exe

OptionStation
os32.exe

RadarScreen
ORradar.exe

SuperCharts SE
scrtse32.exe

QuoteMonitor
orquote.exe

EasyLanguage PowerEditor
oredit.exe

Omega Research Internet Browser
ORIB.exe

NewsMonitor
ORNews.exe

Tracking Center
ORGTCC.exe

Message Log
ORPLog.exe
<

Ciao,
Michael

Powered by: Burning Board 1.1.1 © 2001 by WoltLab